Automatic BGA Rework Station For LED Repairing
1. Suitable for LED lamp beads repairing, size of micro LED components not less than 0.6*0.6mm can be repaired 2. Suitable for LED lamp beads of tape packaging and bulk materials, Also any BGA and components which are difficult to repair. 3. High solution optical alignment system, accurate LED...
شرح
Automatic BGA Rework Station For LED Repairing
Total Power | Max 5000W |
voltage
| AC 220V±10% 50/60 Hz |
Top heater power | 1200W |
Bottom heater power | 1200W |
IR power | 2400W |
Hot air temp | 400℃ (Max) |
Preheating temp | 400℃(Max) |
Positioning | V-groove +laser positioning+ universal fixture |
PCB size |
Max 410×370 mm |
Preheating size | 370mm×270mm |
Chip type | BGA, QGN, CSP, POP, QFN, Micro SMD, LED lamp beads
|
Chip size | Max 80×80mm Min 1×1 mm |
Dimensions | L640×W630×H900 mm |
Temperature sensor | 4 pcs |
1.Suitable for LED lamp beads repairing, size of micro LED components not less than 0.6*0.6mm can be repaired
2. Suitable for LED lamp beads of tape packaging and bulk materials, Also any BGA and components which are
difficult to repair.
3. High solution optical alignment system, accurate LED components positioning, ensure precise mounting.
4. Optical alignment is controlled electrically, can rotate automatically
5. Mounting head built-in pressure testing device, to protect the PCB
6. built-in infrared laser positioning, fast positioning for PCB.
7. Adopt HIWIN precision guide rail for up and down movement system, ensure reliable and accurate running
8. Adopt up and down alignment for top and bottom heater, heating for an appointed local zone, prevent PCB to
turn yellow.
9. The bottom heater up and down manually, can adjust the heating height in real-time.
10. Adopt ceramics infrared radiator for IR heater, heating stably and uniformly with a long service life
11. The human-machine interface has multiple operation modes and permission, soldering, desoldering and mou-
nting manually, easy operation.
12. High-resolution touch screen, which is up to 800*600 pixel
13. Adopt joystick control for alignment system, no need setting Complicated parameters
14. Adopt Delta double ball bearing flow fan for air supply, no need external air source
15. Adopt DCCE 6 channel module for the temperature control system, automatic PID adjustment
16. Monitoring heaters in real-time, when an accident happens, relevant sensors will send a signal to PLC,
which will close the output channel and display fault condition. Protect itself automatically